Search results for "Decreased Visual Acuity"

showing 3 items of 3 documents

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Acute endothelial failure after cosmetic iris implants (NewIris®)

2011

We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryCase Reportendothelial failureNewIrisEndothelial cell counteye diseasescosmetic iris implantsSurgeryOphthalmologymedicine.anatomical_structureCorneal edemaIntraocular lensesOphthalmologyDecreased Visual AcuitymedicineImplantsense organsIris (anatomy)businessClinical Ophthalmology (Auckland, N.Z.)
researchProduct

Subtle retinal pathology in amyotrophic lateral sclerosis

2014

Amyotrophic lateral sclerosis (ALS) is characterized by neuro-ophthalmological abnormalities beyond disturbed oculomotor control such as decreased visual acuity and disturbed visual evoked potentials. Here we report retinal alterations in a cohort of 24 patients with clinically definite (n = 20) or probable (n = 4) ALS as compared to matched controls. High-resolution spectral domain optical coherence tomography with retinal segmentation revealed a subtle reduction in the macular thickness and the retinal nerve fiber layer (RNFL) as well as a marked thinning of the inner nuclear layer (INL). Our data indicate an unprecedented retinal damage pattern and suggest neurodegeneration beyond the mo…

Pathologymedicine.medical_specialtymedicine.diagnostic_testgenetic structuresbusiness.industryGeneral NeuroscienceNeurodegenerationNerve fiber layerRetinalmedicine.diseaseeye diseaseschemistry.chemical_compoundmedicine.anatomical_structurechemistryOptical coherence tomographyMotor systemDecreased Visual AcuityInner nuclear layermedicineNeurology (clinical)sense organsAmyotrophic lateral sclerosisbusinessBrief CommunicationsAnnals of Clinical and Translational Neurology
researchProduct